Fuse Check/Replacement - Nilfisk SC400 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FUSE CHECK/REPLACEMENT

1.
Disconnect the battery connector (29).
2.
Remove the screws (A, Fig. 10), then carefully remove the electrical component box cover (B).
3.
Check the following fuses for integrity:
(C): F1 (40 A) circuit breaker, brush motor
(D): F2 (30 A) blade fuse, vacuum system motor.
(E): F3 (5 A) blade fuse, solenoid valve and electronic board
(F): F4 (20 A) glass fuse, brush disengagement system
4.
Replace the fuse, when the component that caused deactivation has fully cooled down.
Battery fuse (F0) check/replacement
1.
Disconnect the battery connector (29).
2.
Remove the recovery tank (30) (see the procedure in Use chapter).
3.
Check or replace the battery fuse F0 (125 A) (B) on the battery connection cable (A, Fig. 11).
A
B
A
Figure 10
Figure 11
USER MANUAL
F
C
E
D
P100632
A
B
P100654
9099612000 - SC400
ENGLISH
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

90873110209087318020

Table des Matières