Fuse Check/Replacement/Reset - Nilfisk SWEEPER SR 1301 B Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FUSE CHECK/REPLACEMENT/RESET

1.
Drive the machine on a level fl oor and engage the parking brake with the pedal (75) and the lever (68).
2.
Turn the ignition key (67) to "0".
3.
Open the hood (22) and fasten it with the support rod (36).
4.
Disconnect the battery connector (25).
Lamellar fuse check/replacement
5.
Remove the cover (A, Fig. 28) and mark the positions of the fuses shown on the adhesive.
6.
Check/replace the relevant fuse among the following (B):
F1 fuse (30 A): Key circuit
F2 fuse (30 A): Filter shaker
F3 fuse (30 A): Vacuum system
F4 fuse (30 A): Hydraulic pump
F5 fuse (10 A): Flashing light (optional)
F6 fuse (10 A): Working light (optional)
F7 fuse (10 A): Hopper actuator
F8 fuse (30 A): Spare fuse
Main fuse check/replacement
7.
Remove the screws (C, Fig. 28), then remove the cover (D).
8.
Remove the nuts (E).
9.
Check replace the main fuse F0 (150 A) (F)
Circuit breaker check
10.
Check for deactivation of one of the following fuses, then reset it after the relevant motor has cooled down:
FA fuse (H, Fig. 28): Right side broom motor circuit breaker
FB fuse (I): Left side broom motor circuit breaker (optional)
FC fuse (G): Main broom motor circuit breaker
Assembly
11.
Assemble the components in the reverse order of disassembly.