FUSE CHECK/REPLACEMENT/RESET

Fuse check/reset
1.
Drive the machine on a level fl oor.
2.
Engage the parking brake.
3.
Turn the ignition key (57) to "O" and remove it.
4.
On the panel (38), check for deactivation of one of the following fuses:
(A, Fig. 8): F1 fuse (10 A), dust vacuuming
(B): F2 fuse (10 A), fi lter shaker
(C): F4 fuse (16 A), ignition key
(D): F5 fuse (10 A), motor auxiliary
(E): F3 fuse (2 A), dust guard system (if equipped)
(F): F6 fuse (10 A), working lights (optional)
(G): F8 fuse, cab blower (if present)
Reset any deactivated fuse, when the component that caused deactivation has fully cooled down.
Fuse and lamellar fuse check/replacement
1.
Drive the machine on a level fl oor.
2.
Engage the parking brake.
3.
Turn the ignition key (57) to "O" and remove it.
4.
Open the fuse box cover (23).
5.
Check the following fuses for integrity:
(A, Fig. 9): Main pump motor fuse F0 (250 A)
(B): Auxiliary circuit lamellar fuse F10 (30 A) (B)
Replace any open fuse.
6.
Close the fuse box (23).
A
B
C
E
D
G
F
Figure 8
SR 1601 B
USER MANUAL
P100338
33019318(2)2010-09 A
ENGLISH
B
A
Figure 9
29
P100339