Fuse Check/Replacement/Reset - Nilfisk SR 1601 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

revised 08/2018

FUSE CHECK/REPLACEMENT/RESET

Fuse Check/Reset
1.
Drive the machine on a level floor.
2.
Engage the parking brake.
3.
Turn the ignition key (57) to "O" and remove it.
4.
On the panel (38), check for deactivation of one of the following fuses (Fig. 8):
(A): F1 (10 A), dust vacuuming
(B): F2 (10 A), filter shaker
(C): F4 (16 A), ignition key
(D): F5 (10 A), motor auxiliary
(E): F3 (2 A), dust guard system (if equipped)
(F): F6 (10 A), working lights (optional)
(G): F8, cab blower (optional)
Reset any deactivated fuse, when the component that caused deactivation has fully cooled down.
Fuse and lamellar fuse check/replacement
1.
Drive the machine on a level floor.
2.
Engage the parking brake.
3.
Turn the ignition key (57) to "O" and remove it.
4.
Open the fuse box cover (23).
5.
Check the following fuses for integrity:
(A, Fig 11): Main pump motor fuse F0 (250 A)
(B): Auxiliary circuit lamellar fuse F10 (30 A) (B)
Replace any open fuse.
6.
Close the fuse box (23).
A
B
C
01/2009
E
D
G
F
Figure 10
INSTRUCTIONS FOR USE
P100338
33019318 - SR 1601
B
A
Figure 11
ENGLISH
P100339
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1330010313300149

Table des Matières