Connections, Operating And Display Elements - Cameo F1 T Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27

CONNECTIONS, OPERATING AND DISPLAY ELEMENTS

F1 T
6
7
1
POWER IN
TRUE1 compatible mains input socket. Operating voltage 100 - 240 V AC / 50 - 60Hz.
2
POWER OUT
TRUE1 compatible mains output socket for mains supply of additional CAMEO spotlights. Ensure that the total current consumption of all
connected devices does not exceed the value specified on the device in amperes (A).
3
FUSE
Fuse holder for 5 × 20 mm micro fuses. IMPORTANT NOTE: Replace the fuse only with a fuse of the same type and values (see inscription
on housing). If a fuse trips repeatedly, please contact an authorized service center.
4
DMX IN
Male 5-pin XLR socket for connection to a DMX control device (e.g. DMX console).
5
DMX OUT
Female 5-pin XLR socket for sending the DMX control signal.
6
OLED DISPLAY
Displays currently active mode and the menu items in the Edit menu.
7
DIM/MENU
Rotary-push encoder for the adjustment and control of the spotlight.
DIM – If one of the DMX modes is enabled and there is no DMX signal to the device, the encoder serves as master dimmer control and you
can set the brightness of the spotlight with values from 000 to 255 by turning the encoder (Quicklight).
Quicklight
000-255
MENU – Push the encoder to access the main menu and select menu items by turning the encoder.
8
DIM / MENU
3
4
FUSE
DMX IN
2
1
POWER IN
POWER OUT
5
DMX OUT
9
BATTERY IN
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F1 dClf1tClf1d