ADDITIONAL FUNCTIONS
Automatic shut-off
If no button is used for 20 min. the instrument will power off automatically.
Sound
Switch the sound function on. The instrument will now show by a sound signal if the horizontal or
vertical position approaches. The closer the position is the denser the sound signal will be.
If the instrument is in correct vertical or horizontal position the sound will be continuous.
Mode functions [1) - 5)]
1) Slope indication in ° (14,5°)
2) Slope indicaton in % (25,9 %)
3) Indication IN/FT (3 1/8 IN/FT)
4) Indication IN/FT (3,10 IN/FT)
5) Indication mm/m (258,9 mm/m)
Keep the mode button pressed to have all mode functions switch fast. The display will not show any
values. Release the mode button to return to the standard indication.
CONNECTION TO CAMERA TRIPOD
With 1/4"-thread (at the bottom side) S-Digit multi + can be connected to a camera tripod.
SPECIAL FEATURE WITHIN THE RANGE OF 0° - 90°
O-setting in any position required:
In the range between 0° and 90° the ZERO layer can be defined in any position.
Start the calibration function in the position required (press CAL longer than 3 sec.) -
wait 3 sec. - press CAL again - wait 3 sec. - press CAL again - finalized.
Do not turn the S-Digit multi + during this process.
Now the ZERO layer is defined in the new position and the application required can be started.
ATTENTION:
We recommend to define the ZERO layer in the horizontal position again when you have finished your
application. Otherwise it may happen that for the following measurements the results can be complete-
ly wrong (e.g. when you work the next day or if another user is working with the unit).