Outfl ow into the wall
When placing the outfl ow into the side wall, make sure that there is distance of at least 50 cm between the outfl ow and the
corners of the building, eaves, gutters, balconies and etceteras. You need not have this distance when the outfl ow runs to at
least the front side of the overhanging part.
You must also take into consideration the place of the outfl ow in relation to the existing ventilation openings,
movable windows and combustion air supply provisions. Please consult the national and local requirements.

Placing possibilities for the pipe system

The total length of the pipe system must never be more than 10 metres excluding the passage through the wall and the
outfl ow. The maximum horizontal length is 3 metres. A 90° square angle counts as a length of 2 metres. A 45° turn counts as
a length of 1 metre.
For the combined fl ue tube and combustion air supply you must apply one of the following set-up possibilities of the Wanders
(M&G or Schiedel Metaloterm) concentric pipe systems: with wall duct, with roof duct, or with roof duct with bend.
Because of the high outer temperatures of the fl ue system ( around ± 150°C) it's not allowed to use
flammable materials near the flue system. Therefore it is advised to surround the flue system, on
locations where it is not in direct view, with non-flammable materials. Make sure this construction is
sufficiently ventilated (per floor) by installing ventilation grids near the floor and the ceiling.
It's not allowed to insulate the concentric fl ue system.
Use universal wall brackets Ø150 mm to attach the sleeving of the concentric channel system [Ø 100
mm - Ø 150 mm].
Select one of the connection possibilities. Then build up the fi rst metre of concentric pipe from the
counterpart in the appliance. If you can see the blue rubber ring in the pipe from above, you will
know that the assembly is correct. Keep a distance of at least 5 centimetres between the outer wall of
the concentric pipe and the ceiling. Always start with 1 meter vertical.
Pay special attention to proper installing when, due to circumstances, a part of the double-walled pipe system must be built in.
Gastype
A (min.-max.)
Nat. gas
1,0 m
Propane
Nat. gas
1,0 - 2,5 m
Propane
all dimensions are exclusive the length of the wall outlet
B
B (min. - max.)
Reducer
NO
0 - 2,0 m
NO
NO
0 - 3,0 m
NO
Gastype
A (min. - max)
Nat. gas
1,0 - 2,5 m
Propane
Nat. gas
2,5 - 10,0 m
Propane
all dimensions are exclusive the length of the roof outlet
GB
Reducer
Ø 60 mm
Ø 60 mm
Ø 40 mm
Ø 45 mm