SUN t/ SUN s
The threshold value for SUN t is pre-set to 04 and for SUN s to 03.
The value – indicates that the sunshade function has been deactivated. The
brightness value can be set to values ranging between 01 (very overcast) and
15 (direct sunlight).
The new setting to be made is shown on the display. The field for the new sun-
light setting flashes.
DELAY st (only when EXPERT MODE is ON)
The delay time t is pre-set to 3 min and the delay time s is pre-set to 15 min.
The delay time t indicates the period between the moment the threshold set-
ting SUN t is exceeded and the control command is executed.
This setting can be made manually.
The delay time s indicates the period between the moment the sunlight reading
falls below the pre-set threshold value SUN s and the 'retract' control com-
mand is executed.
This setting can be made manually.
END POSITION
The end position is the point the sun protection system reaches when fully re-
tracted or extended.
INTERMEDIATE POSITION
The intermediate position lies between the (retracted and extended) end posi-
tions of the sun protection system and can be freely selected. The sun protec-
tion system can be moved into this position from the retracted end position after
programming.
To do so, press the EXTEND button twice in rapid succession.
When the system is in venetian blind mode, a reverse control command will be
automatically executed following the extend control command, provided a re-
verse position has been pre-set.
FABRIC TENSION/REVERSE
The fabric tension/reverse position lies between the (retracted and extended)
end positions of the sun protection system/venetian blind and can be freely se-
lected. This function allows you to pull your awning fabric taut.
In the case of venetian blinds, the blind slats are turned.
To do so, press the RETRACT button twice in rapid succession.
WINTER OFF/ON
If the WINTER ON function has been activated, no automatic and manual control