8.

Lighting the Fire

The firing up phase should be as short as possible,
since higher emissions can occur during this phase.
The slider settings described in Table 1 are rec-
ommendations that were determined under con-
formance testing conditions, in compliance with
the relevant standard. Depending on the weather
conditions and the draught capability of your chim-
ney, accordingly adjust the slider positions for your
Lisboa to the local conditions.
NOTE!
The Lisboa may only be operated when
the fire box door is closed; the fire box
door may only be opened to add fuel.
WARNING!
Never use spirits, petrol, or other flamma-
ble fluids to light the stove.
CAUTION!
The door handle can become hot during
operation. When adding more wood, pro-
tect your hands with the oven gloves in-
cluded.
40
Lighting the Fire
Procedure
Position of Control
Elements
Switch air slider to the
Pull out the air slider out
heating-up position.
completely across the
red mark.
Pile up any remaining ash
and unburned charcoal
into the centre of the
Delhi
combustion chamber.
Open fire grate.
Pull fire grate slider all the
way out.
Place 4-6 small pieces of
wood with an approx. Ø of
3-6 cm and max. 1,5 kg in
the middle of the burning
chamber. Layer these
cross-wise on top of each
other. Place approx. 0.5 kg
of wood shavings on top
as a firelighter.
Light the kindling/ignition
material.
Stop the heating phase
Push in the air slider until
as soon as the fuel is
the red marker is no longer
completely ignited.
visible.
Close fire grate.
Push in fire grate slider.
Tab. 1
9.
Adding Fuel / Heating at Nominal

Thermal Output

More fuel should be added to the fire when the
flames from the previous burning off phase have just
gone out.
Adding Fuel / Heating at Nominal Output
Procedure
Position of
Control Elements
Adjust the combustion air.
Set air slider between
position 2 and 3.
Close fire grate.
Push in fire grate slider.
Add two logs weighing
approx. 1.3 kg total, place
them with the ends facing
the front of fire box. Only
add one layer of fuel.
Tab. 2
CAUTION!
Please ensure that the logs are inserted
with sufficient distance (at least 5 cm)
from the furnace window.