5.5 Installing the device

At low sub-zero temperatures, the device should
be stored at room temperature for 24 hours
before installation and commissioning.

5.5.1 Mounting distances

300
Fig.: 14. Mounting distances (mm)
The specified mounting distances are minimum distances
for unrestricted access during operation, maintenance and
repair.
16
300
300

5.5.2 Wall mounting

MENNEKES recommends mounting at an ergo-
nomically sensible height depending on the
height of the body.
Fig.: 15. Drilling jig
f Mark the mounting holes using the supplied drilling jig
(1) and a spirit level.
For installation on concrete, brick and wood walls,
use the included installation hardware. For other
surfaces, a suitable on-site mounting method
must be chosen.
f Drill holes in the wall with the diameter required by
selected mounting material.
f Route cables to the positions indicated on the drilling jig.
Approx. 45 cm of cable are required for the sup-
ply line inside the device.
f Insert cables through one of the cable entries in the
device. To do this, you need to make a hole in the
respective membrane.
1