THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Rated power
Water heating power
Thermal power transferred to the environment
Yield / Ef ciency
Emissions CO 13% O
2
Fume temperature
Draught
Fuel consumption
Maximum operating pressure
Temperatura massima d'esercizio
Water capacity
System return (male)
System ow (male)
Heating capacity *
ø female smoke outlet (H min. 4 mt)
ø external air inlet
Weight including packing
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume ow capacity
N.B.: DATA PROJECT (Refer to standard EN 13229)
* The heatable room dimensions are calculated on the basis home insulation in compliance with Italian law 10/91, and subsequent
changes together with an expected heat output of 33 Kcal/m³ per hour.
* It is also important to consider the position of the boiler- replace in the room to be heated.
* * boiler temperature is 70° - (ðT=25K)
The data shown above is purely indicative.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
N.B.
- Any unauthorised modi cation is forbidden
- Use spare parts recommended by the manufacturer
- The use of counterfeit parts results in the guarantee becoming null and void
GENERAL INFORMATION
according to EN 13229
32,5
26
18
80
0,194
243
12
7,1
1,5
90
90
1"
1"
680
25
10
490
26
292
28,2
- 28
-
8
6
kW
kW
kW
kW
%
%
°C
Pa
kg/h
bar
°C
litres
inches
inches
cm
cm
kg
kW
°C
Pa
g/s