Troubleshooting

In purchasing the cable detector, you have acquired a product which has been designed to the state of the
art and is operationally reliable. Nevertheless, problems or errors may occur. For this reason, the following
is a description of how you can eliminate possible malfunctions yourself.
Always follow the safety instructions!
Error
The device does not work.
No or very weak
output signal
at the transmitter.
Check the fuse in the transmitter LSG-10B
An integrated fuse protects the transmitter from wrong operation or overload. The ceramic high perfor-
mance fuse must only be replaced by a specialist.
In the following, we describe how to reliably recognise a defective fuse:
Disconnect all the measuring lines from the measuring circuits.
Switch on the transmitter and select signal level 1.
Connect a measuring cable to the red measuring socket.
Switch on the receiver and move the sensor tip to the measuring cable.
Plug the open end of the measuring line into the black measuring socket of your transmitter.
If the signal level doubles, the fuse is okay. If the signal level at the receiver does not change, the inter-
nal fuse is defective.
Repairs other than those described above may only be carried out by an authorised
specialist. If you have queries about handling the measuring device, our technical
support is available under the following telephone number:
Voltcraft®, 92242 Hirschau, Lindenweg 15, Tel.-No. 0180 / 586,582 7.
48
Possible cause
Is the battery dead?
The internal fuse is
defective.
Remedy
Check the status.
Replace batteries
Please contact our technical
customer service.