Storage

7
Storage
Storing the whole system:
– Remove filter and rechargeable battery.
– Dry the components in a container or cabinet. Store them
dry and clean and protect them from direct sunlight and
thermal radiation.
Storing rechargeable batteries:
– Deeply discharged batteries may get damaged after
prolonged storage. Charge the rechargeable batteries to
50 to 70 % prior to storage.
– If storage lasts for over 6 months, charge the
rechargeable batteries intermittently.
– Do not store rechargeable batteries for prolonged periods
outside the recommended temperature range. This might
reduce the remaining capacity and number of potential
charge cycles.
8

Disposal

This product must not be disposed of as municipal
waste. It is therefore marked with the adjacent symbol.
This product can be returned to Dräger free of charge.
Please contact your national Dräger Sales Organisa-
tion or Dräger for more information.
Batteries and rechargeable batteries must not be dis-
posed of as municipal waste. They are therefore
marked with the symbol on the left. Collect batteries
and rechargeable batteries according to local regula-
tions and dispose of at battery collection centres.
9
Technical data
9.1
Overall system
Flow rate of respiratory pro-
tective device/helmet/visor:
Flow rate of half/full face
mask:
Rated period of service:
1)2)
Operating temperature
Working and storage area
1)
humidity
1)
Storage temperature
Noise:
International Protection Code IP 65
1) Battery charger and rechargeable batteries, see separate information
in this chapter. Other components, see corresponding instructions for
use.
2) For X-plore 8700 -10 °C to +50 °C.
RFID
Technology
Frequency range
24
170/190/210 L/min
115/130/145 L/min
4 hours with standard
rechargeable battery
8 hours with long-life
rechargeable battery
-10 °C to +60 °C
≤ 95 % relative humidity
-20 °C to +60 °C
approx. 64 dB(A)
Induction transfer
13553 to 13567 kHz
Broadcast transmission
capacity
Bluetooth
Technology
Frequency range
Broadcast transmission
capacity
9.2
Rechargeable batteries
1)
Operating temperature
Operating/storage area
humidity:
Storage temperature
Charging temperature:
1) For rechargeable batteries for X-plore 8700 in explosion-hazard areas
-10 °C to +50 °C.
Standard rechargeable battery
Charging time:
Operational life time after a
full charge
Rated voltage
Rated capacity:
Stored energy
1) Varies depending on the preset flow rate and the employed filter and
breathing connection type
Long-life rechargeable battery
Charging time:
Operational life time after a
full charge
Rated voltage
Rated capacity:
Stored energy
1) Varies depending on the preset flow rate and the employed filter and
breathing connection type
9.3
Standard battery charger
Input voltage
Input current
Output voltage
Output current
International Protection Code IP 30
Operating temperature
Operating/storage area
humidity:
Storage temperature
Instructions for use
-2.30 dBµA/m (10 m)
FHSS 2.4 GHz (BT 2.1 +
EDR)
2402.0 to 2483.5 MHz
0.97 mW / -0.14 dBm EIRP
-10 °C to +60 °C
≤ 95 % relative humidity
-20 °C to +50 °C
0 °C to +50 °C
< 4 hours
1)
approx. 4 hours
10.8 V
3.35 Ah
36 Wh
< 4 hours
1)
approx. 8 hours
10.8 V
6.70 Ah
72 Wh
16 V
3.75 A
9 - 12.6 V
4 A
0 °C to +50 °C
≤ 95 % relative humidity
-20 °C to +50 °C
|