Sabotage contact
The alarm control centre housing is protected by a sabotage contact. This contact is internally connected
to loop 8, which is programmed as a 24 hour loop.
The sabotage contact is an NC contact, which means that both contacts are closed/bridged
when the housing is closed.
Potentiometer
There is a potentiometer on the alarm control centre circuit board. This potentiometer maintains the fac-
tory setting for the charging voltage for the rechargeable battery (13.7 V/DC). The potentiometer has been
sealed so that it cannot be adjusted.
Do not make any changes to the potentiometer, this can lead to destruction of the rechargeable
battery or may lead to an error in the operation of the alarm control centre.