Operating And Display Elements - Komet Vacuboy Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and Putting into Operation
6.2

Operating and display elements

Important!
All settings are saved even in case of a power failure.
Master switch
To switch on the machine:
Standard
-
Switch to 1
for operation with GreenVac fitting: Switch to 2
-
To switch off: Switch to
GreenVac
Important!
Wait about 5 seconds after switching off before switching the
machine back on again to ensure that the control system is able to
operate correctly.
Operating Instructions- Translation
0
Note!
The vacuum chamber is soiled with oil.
If you switch off the machine during the packaging process by pressing
the main switch, e.g. in order to clean the machine with closed lid, it
might occur that oil from the vacuum pump enters into the chamber.
Do not switch off the machine by pressing the main switch during
the packaging process.
Unhook the gas spring in order to close the lid.
VAC-STOP button
To set the evacuation time
(between 2 and 40 seconds, increment 1 second)
press the VAC-STOP button when the cover is open
-
-
change the evacuation time by pressing the
or
Abort the vacuum procedure, e.g. if liquids are boiling during
the vacuum procedure (vacuum stop) and
cancel service program:
Press the VAC-STOP button.
-
Note!
Boiling hazard.
When packaging liquid the evacuation time must be selected so
that the vacuum does not reach more than 95 % (vacuum gauge
display between 0 and -0.95).
19 04 249 - 01.01.2012
buttons
Eng - 14 /32

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Plusvac 20Plusvac 21Plusvac 80

Table des Matières