Télécharger Imprimer la page

RIB K500 Mode D'emploi page 30

Masquer les pouces Voir aussi pour K500:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G
B
ELECTORNIC BRAKE
If the low speed in approaching is disabled (DIP8 ON), is preferable turn the DIP7 ON to
enable at least the electronic brake that permits to win the gate leaf inertia when the gate
reaches the close or open limit switches.
GRADUAL START
With DIP 9 in the ON mode, the gate starts to move gradually for 1 second only.
LED WARNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (CRX version only)
DL3 - open limit-switch contact (NC) (red)
DL4 - close limit-switch contact (NC) (red)
DL5 - gate closing M1 (red)
DL6 - gate opening (green)
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
DL9 - Pedestrian opening button (red)
POINT C
- MOTOR ROTATION DIRECTION CHECK
This operation is meant to help the installer during the installation (commissioning) and for
further future controls.
1 - Unlock the operator with the Manual Release, install the limit switch plates, swing open
the leaf about halfway and lock the operator.
2 - Turn DIP1 to ON position, LED DL1 starts blinking
3 - Press and hold the PROG button, the gate will open or close. Release the button and the
gate will stop. Press and hold again, the gate will move in the opposite direction.
The K control board has two movement leds
- DL6 the GREEN led for OPENING
- DL5 the RED led for CLOSING
When you press and hold the PROG button, if the gate opens with the green led on then
you may proceed to step 4.
If the gate moves in the wrong direction compared with the movement leds:
- turn OFF the main AC power
- reverse the V and W motor cables position (the blue motor cable must be
always in the U position)
- reverse the limit switch wires marked LSO and LSC
- turn ON the main AC power and check again the motor direction
4 - After 2 seconds motor starting and for the next 10 seconds motor working, the torque
control is automatically activated. Set the motor torque by the TORQUE Trimmer which
varies the output voltage to the head of the motor (turn clockwise to increase torque).
5 - After other 10 seconds motor working, the low speed control is automatically activated
(DIP8 OFF). Set the motor low speed by the LOW SPEED Trimmer to select the gate leaf
low speed in approaching.
6 - Press and hold the PROG button to close completely the gate. Turn DIP1 to OFF, the RED
led DL1 will stop blinking.
During Point C procedure, safety devices (photocells and safety strip) are not
active.
(#) In Point D and Point E procedures, all the safety devices (photocells and safety strip)
will be active, so they must be properly installed and connected to the control board. Any
changing of the safety devices input state, will stop the Point D and Point E procedure that
must be repeated from the beginning.
POINT D
- PROGRAMMING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG. Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out motor and the gate
travelling will be stored. The gap of time between now (stop of motor) and the next
pressing of the PROG. button (see step 5 below) will be then stored as waiting time for
Automatic Closing feature.
5 - Press PROG. button, gate closes and the Automatic Closing time is stored (see DIP3
function to enable or disable the Automatic Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D procedure.
Closing of the gate will be carried out at normal speed and only on approaching total
closing at low speed (depending on the adjustment of LOW SPEED trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor stops.
8 - Turn DIP2 to OFF position
During Point D procedure, safety devices (photocells and safety strip) are active.
POINT E
- PROGRAMMING OF PEDESTRIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts blinking slowly
4 - Press the pedestrian pushbutton PED. BUTT, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing, press the pedestrian
pushbutton PED. BUTT to stop the travel (thus defining the opening stroke of the
motor). The gap of time between now (stop of the motor) and the next pressing of the
PROG. button (see point 6 below) will be stored as waiting time for Pedestrian Automatic
Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, gate closes and the Pedestrian
Automatic Closing time is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
7 - Turn DIP1 to OFF position
8 - Turn DIP2 to OFF position
During Point E procedure, the safety devices (photocells and safety strip) are
active.
POINT F
- PROGRAMMING RADIO CODES FOR COMPLETE OPENING
(UP TO 30 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel A) within the 10 seconds proscribed. If
the remote control has been correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next
remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The
red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 2 to OFF.
7 - You have completed the procedure
PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING
You can only delete the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press and hold the PROG button for 5 seconds. The green DL2 LED will flash twice to
confirm that the stored codes have been deleted.
4 - The red programming DL1 LED remains active and you can programme new codes as
shown above if required.
5 - Reposition DIP 1 to OFF and DIP 2 to OFF.
6 - You have completed the procedure.
HOW TO CHECK IF THE MEMORY IS FULL FOR RADIO CODES USED ONLY FOR
COMPLETE OPENING
You can only check the memory if the gate is closed.
1 - Position DIP 1 to ON and then DIP 2 to ON.
2 - The green DL2 LED will flash 6 times if the memory is full (30 codes have been stored).
3 - After this, the DL1 programming LED will remain active for 10 seconds, so that you can
delete all codes if required.
4 - Reposition DIP 1 to OFF and DIP 2 to OFF.
5 - You have completed the procedure
POINT G
- PROGRAMMING RADIO CODES FOR PEDESTRIAN OPENING
(UP TO 30 CODES - ONLY FOR CRX MODELS)
You can only programme the codes if the gate is closed.
1 - Position DIP 1 to ON and then DIP 3 to ON.
2 - The red programming DL1 LED will flash ON and OFF, one second on each, for 10
seconds.
3 - Press the remote control button (normally channel B) within the 10 seconds proscribed. If
the remote control has been correctly programmed, the DL2 LED (green) will flash once.
4 - The code programming time resets automatically so that you can programme the next
remote control.
5 - To finish programming, let 10 seconds pass and then press the PROG. button briefly. The
red DL1 LED will stop flashing.
6 - Reposition DIP 1 to OFF and DIP 3 to OFF.
N.B: IF THE DL1 LED CONTINUES TO FLASH RAPIDLY, THIS MEANS THAT DIP 1
IS STILL POSITIONED TO ON AND ANY MANOEUVRE HAS BEEN DELETED.
7 - You have completed the procedure.
PROCEDURE FOR DELETING ALL RADIO CODES USED ONLY FOR COMPLETE OPENING
You can only delete the codes if the gate is closed.
30

Publicité

loading

Ce manuel est également adapté pour:

K2007Aa33694Aa33695Aa33753wAa33693Aa33696