Télécharger Imprimer la page

RIB K500 Mode D'emploi page 26

Masquer les pouces Voir aussi pour K500:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G
INSTALLATION K500
B
CHECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
N.B.: Gate features must be uniformed with the standards and laws in force. The door/
gate can be automated only if it is in a good condition and its conditions comply with the
EN 12604 norm.
- The door/gate leaf does not have a pedestrian door. In the opposite case it is necessary
to take the appropriate steps, in accordance with EN 12453 norm (for instance; by
preventing the operation of the motor when the pedestrian door is opened, by installing
a safety microswitch connected with the control panel).
- Besides the electrical or mechanical limit switches available on the operators, there must
be, on both ends of the installation, a fixed mechanical stopper which stop the gate in
the unlikely event of ill functioning of limit swithces on the operators. For this reason the
fixed mechanical stopper must be of an adeguate size to withstand the static and kinetic
forces generated by the gate (12) (fig. 2).
- Gate columns shall have anti-derailment guides on their top (fig. 3), to avoid the
unintentional gate release.
N.B.: Remove mechanical stops like the one in fig. 3.
No mechanical stops shall be on top of the gate, since these mechanical stops are not
safe enough.
Parts to install meeting the EN 12453 standard
Skilled persons
COMMAND TYPE
(out of public
with manned
operation
with visible impulses
(e.g. sensor)
with
not
visible
impulses
(e.g. remote control
device)
automatic
C and D, or E
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013
B: Key selector with manned operation, like code ACG1010
C: Adjustable power of the motor
D: Safety strips and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
E: Photocells, like code ACG8026 (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
RELEASE
To operated after the power supply to the motor has been interrupted.
In order to work manually on the gate, you just need to insert the fitting key and rotate it
3 times counterclockwise (fig. 4).
In order to carry out the manual operation of the gate leaf the followings must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the operator;
- That the physical effort necessary to move the gate leaf should not be higher than 225
N, for doors/gates for private dwellings, and, 390N for doors/gates for commercial and
industrial sites (values indicated in 5.3.5 of the EN 12453 norm).
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
area*)
A
B
non possibile
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
26
2
3
4

Publicité

loading

Ce manuel est également adapté pour:

K2007Aa33694Aa33695Aa33753wAa33693Aa33696