NovoPress ACO401 Manuel D'utilisation page 33

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 39
1.
Check that the nominal size of the press fitting matches the nominal size of the press
collar.
Information!
Comply with the system supplier's instructions when positioning the press collar on
the press fitting.
CAUTION!
There is a risk that the press collar will break if it is positioned
incorrectly
If the press collar is positioned incorrectly on the fitting the press collar may become
damaged.
Therefore
– Arrow (A) must point to line (B). (Fig. 7)
– If this is not the case, remove the press collar again and reposition it.
2.
Swivel the outer shells of the press collar outwards as far as possible and then position
the press collar on the press fitting.
3.
Close the press collar. (Fig. 6)
4.
Open the adaptor jaw fully using the grip.
WARNING!
Risk of injury from ejected fragments
If the adaptor jaw is positioned on the press collar incorrectly, the adaptor jaw and the
press collar may break.
Therefore
– Claws (21) of the adaptor jaw must grip pins (22) of the press collar. (Fig. 11, 12 +
13)
5.
Position the adaptor jaw on the press collar as follows.
Push claws (21) of the adaptor jaw as far as possible into grooves (24) in the press collar.
(Fig. 10)
6.
Close the adaptor jaw using the grip.
Information!
Ensure there is no gap between the segments of the press collar when
the pressing operation is complete.
7.
In order to start the process, press the start button and hold it down.
8.
After the pressing operation has been completed, open the adaptor jaw using the grip
and detach it from the press collar.
9.
Open the press collar and remove it.
27