• TIME END POSITION/INTERMEDIATE POSITION/FABRIC TENSION (TILT
for venetian blind) (only where SHADE TIME or AUTO SHADE TIME is
programmed)
• SUN END POSITION/INTERMEDIATE POSITION/FABRIC TENSION (TILT
for venetian blind)
• Language selection (ENGLISH)
• SUMMER/WINTER (Automatic summer/winter time adjustment)
To carry out settings, press the OK button repeatedly until you come to the de-
sired menu item.
SUN
/ SUN
The threshold value is preset to 04 for SUN
At this value – the sun protection function is off. The brightness value can be
set to anywhere between 01 (heavily overcast) and 15 (direct sunlight). The
sun value that has been set is indicated on the display. The value to be set
flashes.
DELAY
(only when EXPERT MODE is ON)
The delay time
The delay time
exceeded and the extend command.
This value can be set manually.
The delay time
denotes the time between the brightness falling below the
SUN
threshold value and the retract command.
This value can be set manually.
END POSITION
When the sun protection system is fully extended or retracted, this is de-
scribed as an end position.
INTERMEDIATE POSITION
The intermediate position is a freely selectable position of the sun protection
system, between the retracted and extended end positions. Once pro-
grammed, this position can be travelled to from the retracted position.
To do so, press the EXTEND button briefly twice in succession.
For venetian blind operation, any tilt which has been set is automatically car-
ried out following the intermediate position.
is preset to 3 mins and the delay time
denotes the time between the SUN
and 03 for SUN
to 15 mins.
threshold value being
.
39 - en