DISASSEMBLY

DANGER!
Risk of poisoning, chemical burns, contamination from escaping medium.
▶ When handling hazardous substances, always take appropriate precautionary measures and wear personal
protective equipment in accordance with the requirements of the medium.
▶ Before disconnecting lines, the medium must be flushed from the entire system.
Risk of injury from high pressure in the system/product.
▶ Before working on the system or product, switch off the pressure and vent/drain the lines.
Risk of injury from improper disassembly.
Improper disassembly may result in injuries as well as damage to the product and the area around it.
▶ Before removal, ensure that the operating personnel are familiar with and completely understand the contents
of the operating instructions.
▶ Observe the safety instructions and intended use.
▶ Only adequately trained personnel may remove the product.
If the T-CUT tubular/pipe module is to be used further after removal, certain conditions must be adhered to
regarding storage (refer to "13 Non-use/Module Storage").
Procedure:
Completely drain the system.
Flush out the rest of the feed solution with water (normal cold tap water) until the concentrate is clear.
Flush the entire system for 20 minutes using warm water. Any concentrate or permeate generated is to be
disposed of.
Completely drain the system.
Disconnect the connections.
Remove the product.
Please consult a representative of Bürkert Fluid Control Systems if you have any questions.
20
english
Type T-CUT
Disassembly