Lenze E82ZAFCC100 Instructions De Montage page 52

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6
Electrical installation
Assignment of the terminals
X3.1/
Designation
20
28
CINH
E1
Digital input
Digital input
E2
59
7
GND1
X3.2/
Designation
"
FES
7
GND1
LO
CAN−LOW
HI
CAN−HIGH
52
Function
Supply of
l
controller inhibit (CINH)
l
digital inputs E1 and E2
Controller inhibit
User−defined,
can also be used as frequency
input (0 ... 10 kHz, configuration
under C0425)
User−defined
External DC−voltage supply
Reference potential 1
Function
Additional HF−shield
termination (large surface
connection to functional earth)
Reference potential 1
System bus LOW (data line)
System bus HIGH (data line)
l
Level
20 V (Ref: GND1)
l
Start = HIGH (12 ... 30 V)
l
Stop = LOW (0 ... 3 V)
0 = LOW (0 ... 3 V)
1 = HIGH (12 ... 30 V)
(Reference: GND1)
24 V DC ± 10 %,
max. 200 mA
Level
EDK82ZAFCC−100 DE/EN/FR 6.0