4
Technical data

Protective insulation

Protective insulation
Protective insulation between bus and ...
l
8200 vector power stage
l
Reference earth / PE (X3/7)
l
Supply for CINH (X3/20)
l
Controller inhibit, CINH (X3/28)

Connection terminals

X3.1/
20
28
E1
E2
59
44
Type of insulation (in accordance with EN
61800−5−1)
Reinforced insulation
Functional insulation
No electrical isolation
Functional insulation
Load capacity: I
= 30 mA
max
Input resistance: 3.3k
Controller inhibit:
l
Start = HIGH (12 ... 30 V)
l
Stop = LOW (0 ... 3 V)
Input resistance: 3.3k
0 = LOW (0 ... 3 V), PLC level, HTL
1 = HIGH (12 ... 30 V), PLC level, HTL
External DC−voltage supply
24 V DC ± 10 %, max. 200 mA