LoRaWAN 863-870 PULSE - Guide utilisateur / User guide version V3.0.0
4.1.9
Reply frame to a request for changing value of a register
Following reception of a downlink frame with the code 0x41, the frame 0x33 is transmitted. It shows
whether the downlink frame (0x41) has been received and gives information on the support status of
the latter.
0
FR
Code
0x33
0x33
Its size is of 5 bytes.
Description of the frame:
EN
Byte 2 : Request status:
- 0x00 = N/A
- 0x01 = success
- 0x02 = success, the value to set is the current register value
- 0x03 = error, incoherency of the request
- 0x04 = error, invalid register
- 0x05 = error, incorrect value
- 0x06 = error, truncated value
- 0x07 = error, access not allowed
- 0x08 = error, other reason
Bytes 3 et 4 : register concerned by the request (if request status different than 0x01).
In the example it gives:
Byte 2 : 0x02 = request successful
Bytes 3 et 4 : 0x012D = 301 (decimal), request concern the register S301
4.1.10

Summary of the conditions of the transmission of the uplink frames

The table below summarizes the conditions of the transmission of the different uplink frames:
Code
0x10
Frames of information on
the product configuration
0x20
Frames of information on
the network configuration
0x30
Keep Alive frame
0x31
Reply frame to a register
value request in a downlink
frame
0x33
Reply frame to a request
for changing value of a
register
0x46
Data Frame without period-
ic data
0x47
Alarm frame
0x5A
Periodic frame with
0x5B
historisation
1
Status
Cf Status
Request status
0xA3
Description
2
3 et 4
PAYLOAD
Concerned register
0x02
0x012D
Sending conditions
Product start-up
Exit from the configuration mode (AT Command)
Reception of a downlink frame 0x01
Product start-up
Exit from the configuration mode (AT Command)
Reception of a downlink frame 0x02
24 hours elapse since the start-up of the product or since the last
transmission of this frame
Reception of a downlink frame 0x40
Reception of a downlink frame 0x41
Exit from the configuration mode (AT command)
Transmission period reached (period defined by register S321) and 1
saving ( defined by S301)
Exceeded flow threshold on one of the two channels (sending only if
the exceeded flow control is enabled by writing a non-zero value in
the S326 or S327 registers).
Transmission period reached (period defined by register S321 and
301)
0x5A for channel A
0x5B for channel B
Page
88
of 103