Operation Of The Leds - ADEUNIS ARF8230CA Guide Utilisateur

Masquer les pouces Voir aussi pour ARF8230CA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LoRaWAN 863-870 PULSE - Guide utilisateur / User guide version V3.0.0
Example :
Register
Value encoding
S320
Hexadecimal
S322
Hexadecimal
S325
Decimal
S328
Decimal
S329
Decimal
S330
Decimal
S331
Decimal
In this example, all the periods during which the flow rate on the channel A is less than 10 pulses /
hour are considered as periods of zero flow. If the total daily number of zero flow periods is less than 3
then it is considered that there is a leak on the channel A.

2.3. Operation of the LEDs

Mode
Product in Park mode
Magnet detection process (1 to 6
seconds)
Product start (after detection of
the magnet)
Joining process (Lora product)
Switching to the Command mode Continuously lit
Product faulty (return to factory) Fixed ON
Value
Result
0x39
Channel A :
Activated
Meter other than gas
Tamper input activated
Channel B :
Activated
Gas meter
Tamper input disabled
0x57
Anti-bounce :
Channel A = 500ms
Channel B = 100ms
60
Flow calculation period (channels A and B) = 60min
10
Leak threshold (channel A) = 10 pulses par hour
0
Leak threshold (channel B) = 0 pulse par hour
Daily periods number under the leak threshold (channel A)
3
= 3
5
Daily periods number under the leak threshold (channel B)
= 5
LED red state
OFF
OFF
OFF
During the JOIN phase: flashing:
50ms on / 1 s off
If the JOIN phase is complete
(JOIN accept):
flashing: 50ms on / 50ms Off
(6x)
LED green state
OFF
ON from detection of the mag-
net up to a maximum of 1
second
Rapid flashing 6 cycles, 100 ms
ON / 100 ms OFF
During the JOIN phase: flash-
ing: 50ms on / 1 s off (just
after the red LED)
If JOIN phase is complete (JOIN
accept):
flashing: 50ms on / 50ms off
(just before the red LED)
Continuously lit
FR
EN
Page
73
of 103

Publicité

Table des Matières
loading

Table des Matières