LoRaWAN 863-870 PULSE - Guide utilisateur / User guide version V3.0.0
5.
PREPARATION
5.1. Dismantling the case
The product is supplied disassembled such that the lower electronic part can be accessed. This part
is where the meter or meters are connected to the screw terminals and where the micro USB port for
configuration of the device.
Once connection of the meters has been finalized and configuration carried out, the case may be
closed.
5.2. Installation of the compression seal
Before connecting your meter cables to the product's screw terminals, you must insert the compression
gland nut and the appropriate seal for your configuration.
3 types of seals are supplied with the PULSE: for a 5 mm diameter cable, for a 3 mm diameter cable,
for 2 x 2.2 mm cables.
Seal for 1 x 5 mm cable
Assembly procedure:
1 - Your meter
2 - Pass the
and its pulse
cable through
interface.
the compres-
sion gland nut.
Seal for 1 x 3 mm
Seal for 2 x 2.2 mm
cable
cables
90
3 - Pass the
4 - Pass the ca-
cable through
ble through the
105
the compression
PULSE'S case
gland seal
plate.
27
5 - Verify that
6 - Connect
the O-ring seal
the ends of
is correctly po-
the meter
sitioned on the
cable to the
case plate and
screw termi-
not twisted.
nals.