Electrical installation
Connection of spring−operated brake
{
Danger!
All power connections (terminal strip X1) can carry dangerous electrical
voltages if the starttec is connected to the mains. For this reason,
de−energise the starttec before beginning to work on it or opening the
housing.
(
Stop!
If you use starttec to switch a spring−operated brake, the starttec type
E71MM402x4Axxx (brake voltage 180 VDC) must only be operated on mains
voltages £ 400 V. Mains voltages > 400 V destroy the brake rectifier.
Note that the brake voltage at X1/B1, B2 is dependent upon the mains voltage:
Mains voltage
3/PE AC 230 V
3(/N)/PE AC 400 V
3(/N)/PE AC 500 V
92
starttec E71MM402x2Axxx
Brake voltage at X1/B1, B2
» 0.89 x U
U
B1B2
L2BN
205 VDC
205 VDC
257 VDC
EDK71MMXXX−020 DE/EN/FR 5.0
E71MM402x4Axxx
» 0.45 x U
U
B1B2
L1L2
103 VDC
180 VDC
Operation not allowed