Lenze starttec E71MM402 Instructions De Montage page 129

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
No.
Designation
C0415
Configuration of
v
digital output
signals
uSEr
1 Digital output
X3/A1
2 Digital output
X3/A2
3 Digital output
X3/A3
4 Digital output
X3/A4
5 AS−I status bit
D0
6 AS−I status bit
D1
L
Setting options
Lenze
Selection
Output of internal digital signals to
terminals or AS interface
3
Status of motor 1
4
Status of motor 2 or direction of
rotation
5
Status of brake
25
TRIP fault message
255
Not assigned
255
Not assigned
Internal digital signals
0
Not assigned
1
PAR−B0 active
2
starttec inhibited
3
Status of motor 1
4
Status of motor 2
5
Status of brake
6
Error in power section
7
fd = 0
8
starttec released/inhibited
9 ...
Reserved
12
13
Overtemperature" warning
14
Reserved
15
CCW rotation
16
Ready for operation
17
PAR−B1 active
18
Reserved
19
Motor overtemperature" warning
(PTC input)
EDK71MMXXX−020 DE/EN/FR 5.0
Commissioning
Code table
IMPORTANT
Motor 1 is running HIGH
Motor 1 is stopped LOW
Motor 2 is running
or CCW rotation
Motor 2 stopped
or CW rotation
Brake is released
Brake is applied
TRIP active
No fault
Only active for variant
E71MM402FxAxxx
Is generated only if
C0119 = 2
7
HIGH
LOW
HIGH
LOW
HIGH
LOW
129

Publicité

Table des Matières
loading