Commissioning
Code table
Code
No.
Designation
18 Reserved
...
24 Reserved
C0411
Level inversion
v
of digital inputs
E1 ... E5
128
Setting options
Lenze
Selection
255
Not assigned
255
External signal sources
0
Not assigned
1
Digital input X3/E1
2
Digital input X3/E2
3
Digital input X3/E3
4
Digital input X3/E4
5
Digital input X3/E5
6
AS−I control bit D0
7
AS−I control bit D1
8
AS−I control bit D2
30 ...
CAN−IN1.W1/FIF−IN.W1
45
Bit 0 (30) ... bit 15 (45)
50 ...
CAN−IN1.W2/FIF−IN.W2
65
Bit 0 (50) ... bit 15 (65)
70 ...
CAN−IN2.W1
85
Bit 0 (70) ... bit 15 (85)
90 ...
CAN−IN2.W2
105
Bit 0 (90) ... bit 15 (105)
200
Bit by bit assignment of FIF control
words (FIF−CTRL1, FIF−CTRL2) from
INTERBUS or PROFIBUS−DP
function module (see also C0005)
201 ...
Digital output signals same as
231
C0415 = 1 ... 31
255
Not assigned
0
E5
E4
4
2
2
0
0
0
1
0
0
2
0
0
3
0
0
...
...
...
31
1
1
EDK71MMXXX−020 DE/EN/FR 5.0
E3
E2
E1
3
2
1
0
2
2
2
0
0
0
0
0
1
0
1
0
0
1
1
...
...
...
1
1
1
IMPORTANT
Only active for variant
E71MM402FxAxxx
Code is individually
adjustable in four
parameter sets
The binary value of the
selection digit controls the
level pattern of the inputs:
l
0: Ex is not inverted
(HIGH active)
1: Ex is inverted (LOW
l
active)
L