Technical Data; General Data - Lenze starttec E71MM402 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Conformity
Standards
Vibration resistance
Climatic conditions
Degree of pollution
Permissible temperature
ranges
Permissible installation
height
Mounting positions
Free space
EMC−18−
Noise emission
Leakage current toward PE
(to EN 50178)
Enclosure−19−
(only with rubber cap on AIF
interface)
Protective measures against Motor overtemperature (input for PTC or thermal contact, I
Protective insulation of
control circuits
Insulation resistance
L
CE
Low−Voltage Directive (2006/95/EC)
EMC Directive (2004/108//EC)
DIN EN 60947−4−2
Semiconductor motor control devices and starters for AC
voltage
Accelerational stability up to 4 g (Germanischer Lloyd, general requirements)
Class 3K3 to EN 50178 (without moisture condensation, medium relative
humidity 85 %)
VDE 0110 Part 2, Degree of pollution 2
Transport
−25 °C ... +70 °C
Storage
−25 °C ... +60 °C
Operation
with motor mounting: −25 °C ... +60 °C
with wall mounting: −25 °C ... +40 °C
0 ... 4000 m amsl
Above 1000 m amsl Reduce rated output current by 5 %/1000 m .
Every mounting position and mounting direction is permissible.
Above
100 mm
Lateral
100 mm
Maintaining requirements to EN 61800−3/A11
Maintaining limit class B to EN 60947−4−2
< 3.5 mA
IP 65
NEMA 250 Type 4
Safe disconnection from mains:
Double/reinforced insulation to EN 50178
Overvoltage category III to VDE 0110
EDK71MMXXX−020 DE/EN/FR 5.0

Technical data

General data

2
t monitoring)
2
79

Publicité

Table des Matières
loading