Commissioning
Code table
Code
No.
Designation
C0161
Current error
C0162
Last fault
C0163
Next to last
fault
C0164
Third to last
fault
C0165
Service code
LECOM
C0170
TRIP reset
v
configuration
C0171
Delay for
Auto−TRIP reset
C0178
Operating hours
C0179
Mains
connection time
C0200
Software MPC
122
Setting options
Lenze
Selection
0
0
TRIP reset by switching the 24 VDC
supply voltage, LOW edge at X3/28,
bus function module or
1
Same as 0 and additionally
Auto−TRIP reset
2
TRIP reset by switching the 24 VDC
supply voltage or via bus function
module
3
TRIP reset by switching the 24 VDC
supply voltage
0.00
0.00
82S8213V_xyz00
z = 1
1 motor, brake = 180 VDC
z = 2
1 motor, brake = 205 VDC
z = 3
1 motor, brake = 180 VDC, ASI
z = 4
1 motor, brake = 205 VDC, ASI
z = 5
2 motors, brake = 180 VDC
z = 6
2 motors, brake = 205 VDC
z = 7
2 motors, brake = 180 VDC, ASI
z = 8
2 motors, brake = 205 VDC, ASI
EDK71MMXXX−020 DE/EN/FR 5.0
s
key
{0.01 s}
60.00
{h}
{h}
IMPORTANT
Display of history buffer
contents
Hand terminal: three−digit
alphanumeric fault
identification
Changes only through
Lenze Service!
TRIP reset via bus
l
function module with
C0043, C0410/12 or
C0135 bit 11
Auto−TRIP reset
l
automatically resets all
faults after the time in
C0171 expires
Display only
Total time terminal
X3/28 = HIGH
Display only
Total time of mains On
Display at PC only
x = main version
y = subversion
TRIP reset via bus
l
function module with
C0043, C0410/12 or
C0135 bit 11
Auto−TRIP reset
l
automatically resets all
faults after the time in
C0171 expires
L

Publicité