Technical Information - Vetus FS3816 Instructions D'installation

Masquer les pouces Voir aussi pour FS3816:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
The top side of the Splash-stop is equipped with a connection for
the breather line. This connection has a turning radius of about 200°.
• Fit the Splash-stop onto the filler cap with the pre-fitted rubber
sleeve and the hose clamp included. Use water or soap, if needed;
do not use oil.
Support the Splash-stop by attach-
ing the strip provided to the deck or
the gangway. The strip can be fitted
on both sides of the splash-stop.
• Fit a filler hose between the Splash-Stop and the tank. Use fire-
proof hose with a 38 mm or 51 mm inner diameter respectively.
Place it such that no mechanical stress is placed on either the tank
or the Splash-Stop.
• Place the breather nipple as high as possible above the level of
the Splash-Stop. This will prevent fuel escaping from the breather
lines.
Choose a location for the breather nipple such that fumes are
not trapped within the ship!
Unpleasant odours can escape through the breather nipple. This can
be prevented by fitting an active carbon filter (the Vetus Odour filter)
onto the breather line. Refer to the relevant instruction manual for
installation of the Vetus Odour filter.
The Vetus Odour filter is only suitable for diesel, not petrol.
• Fit the breather hose using fireproof hose with a 16, 19, 22 or 25
mm inner diameter, depending on the version.
The first section of the breather hose, which is also the feed for fuel
caught in the Splash-Stop, should run from the tank to the RETURN
connection.
The second section of breather hose should be run from the VENT
connection to the breather nipple.
The breather hose must be fitted such that there is a continuous up-
ward slope in relation to the tank.
vetus® Splash-Stop
W
arning
• Fasten all hose connections with 2 stainless steel hose clamps!
FS3816
The deck fitting and the other metal parts that may come in contact
with the fuel, must be grounded to prevent sparks from static elec-
tricity. Use a wire cross-section of 1 mm
green/yellow.
4
Maintenance
Check the breather nipple regularly and clean the steel breather nip-
ple strainer whenever necessary.
Check annually:
- the anti-splash sleeve and re-
place when necessary.
- the hoses and hose connec-
tions for possible leakage and
replace hoses and hose clamps
when necessary.
5

Technical information

Reservoir volume : 2 litres
Material
: Polyethylene
Weight
: 1.3 kg
Connections
Filler cap
FS3816
ø 38
FS5116
ø 51
FS5125
ENGLISH
FS5116
FS5125
2
minimal, insulation colour
Filler hose
Breather hose
ø 38 / ø 51
ø 16
ø 51
ø 25
040402.02
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fs5116Fs5125

Table des Matières