Fine Adjustment for Each Input Signal

Adjusting the Video Input Signal

Fine magnetic focus and AQP/DQP adjustments

96
(EN)
Adjustments
After the registration adjustment is performed without an input source and
the adjustment data is saved as the standard data, input an external signal
and fine adjust for each input signal.
1
Connect a video signal to the VIDEO IN jacks or on the signal interface
board installed to the INPUT B section.
2
Select the video input source by pressing the INPUT SELECT VIDEO
and the SELECT keys or the INPUT SELECT B key on the remote
control.
3
Display the INPUT INFO menu and check that the horizontal
frequency of the input signal (fH) indicates 15.7 kHz.
To display the INPUT INFO menu, press the MENU key, select INPUT
INFO with the V or v key, then press the ENTER key.
4
Adjust the magnetic focus and AQP/DQP for each input signal.
For details, see "Adjusting the green magnetic focus and AQP/DQP" on page
68 (EN).
1
Press the PATTERN key to display the 9 × 9 DOT pattern.
2
If necessary, fine adjust the magnetic focus, AQP and DQP.
For details, see "Adjusting the green magnetic focus and AQP/DQP" on page
68 (EN).
3
Press the MEMORY key to save the adjustment data.
Note
Do not hold down the MEMORY key in step 3.
Defocused level in magnetic focus adjustment mode
Optimized uniformity can be obtained by setting the magnetic focus "ALL"
and the "4PA" adjustment levels to the defocused levels. The projector is
designed to automatically defocus the red and blue "ALL" adjustment data.
The defocused level varies with the color temperature and the horizontal
frequency (fH) of the input signal. When the magnetic focus mode is
canceled or the MG FOCUS key is pressed again during the magnetic focus
adjustment, the defocused value listed in the tables on the next page is
automatically added to the "ALL" adjustment level, and the magnetic focus
"ALL" data is defocused. The "4PA" data, however, is not defocused
automatically.
If you give priority to uniformity over spot focus, adjust "4PA" completely,
then subtract the value in the table from the "4PA" adjustment level. If you
give priority to spot focus over uniformity, adjust the magnetic focus
"ALL" completely, then subtract the value in the table, which will be added
to the data with automatic defocusing function, from the "ALL" adjustment
level.