Example 2: Operating mode „Multi-User"
0000 *
0 #
0 32 #
 0 32 #
 02 223 #
 03 3322 #
 04 555 #
2  654 #
2 2 6325 #
40 2 #
5 #
72 0 #
*
Call programming mode with the master code
(basic setting ex works „0000"), the yellow LED
is lit permanently.
Attention - if another master code is already
programmed, it must be used, of course!
Use operating mode „Multi-User"
Attention - if the operating mode „Single-User"
has been activated first, this will delete all codes
and pre-settings (except for the master code)!
Programme master code to „3289"
Programme user code „01" to „8321"
Programme user code „02" to „11223"
Programme user code „03" to „33221"
Programme user code „04" to „8555"
Programme code for access lock for user number
„1" to „6854"
Programme code for access lock for user number
„2" to „6325"
Relay output is activated for 2 seconds at correct
user code
Access lock is to work in toggle operation at
correct code (the access lock is activated or
deactivated at very input of the code)
Code lock is locked for 15 minutes after 10 wrong
code inputs
Terminate programming mode; then the yellow
LED flashes slowly (standby)