Remove The Ventilation Tower And Empty The Reservoir; Cleaning The Grease Filters; Place Back The Ventilation Tower; Regenerate The Monoblock Filter (In Case Of Recirculation) - Novy 1811 ONE Mode D'emploi

Masquer les pouces Voir aussi pour 1811 ONE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.2 Remove the ventilation tower and empty the re-
servoir
Water entering the suction opening is collected in a re-
movable reservoir (volume 150 ml).
• Press the [ symbol ] key to make the tower move up.
• Hold the tower with two hands on both sides. Do not
pull up the tower only by the glass.
The four white LEDs start flashing as soon as the tower
is removed from the cooking plate. Do not place the
tower on the cooking plate. You can see the remov-
able reservoir through the opening. Take out the wa-
ter reservoir and empty it. When this reservoir is full,
it will run over in the overflow reservoir (200 ml). This
can be dried with a cloth. When the overflow reservoir
has become full as well, the excess water will end up
in a container (100 ml). This can be dried with a cloth.
You can also open a slide at the bottom of the unit to
remove the water.

6.3 Cleaning the grease filters

After 20 cooking hours, white led next to the symbol
starts burning. Remove the suction tower from the
cooking plate as described in section 6.2.
Turn the glass a quarter of a turn to the right to be able
to remove the glass from the tower. You will see the two
metal fat filters inside the tower right away.
Cleaning the filter
• in the dishwasher
• manually: in a hot solution of water and a liquid de-
tergent. Rince and allow to dry completely.
The previous instructions need to be followed. If
not an increased fire hazard may occur.
After cleaning:
• Place the filters and the glass back onto the tower.
• Place the tower back into the opening.
• Press the [ ] key for three seconds.

6.4 Place back the ventilation tower

Place back the removable water reservoir and the ven-
tilation tower at their respective places in the centre
of the cooking plate. A magnet keeps the ventilation
tower nicely at its place. Now press the key to move the
tower down and initialise it.
6.5 Regenerate the monoblock filter (in case of re-
circulation)
The white indicator lamp starts burning after 200 work-
ing hours (time to regenerate the monoblock filter).
If recirculation has been selected, the unit has been
connected to an exhaust box with a Monoblock recir-
culation filter.
Regenerate the monoblock filter
• The Monoblock can be regenerated up to 12 times.
This is done in the oven.
• Place the filter in the oven for 1 hour at 120°C. Pro-
vide sufficient fresh air in the room where the oven
has been placed, as smells can be released. Smells
can be released when baking certain kinds of fish.
In this case it is best to immediately regenerate the
filter in the oven.
Reset the monoblock indication
• Put the monoblock filter back in the exhaust box.
• Press the
key for three seconds.

7 WHAT TO DO IN CASE OF A PROBLEM

7.1 Indications if the cooking plate

The hob or the cooking zone doesn't start-up:
• The hob is badly connected on the electrical net-
work.
• The protection fuse cut-off.
• The looking function is activated.
• The sensitive keys are covered of grease or water.
• An object is put on a key.
The control panel displays [ U ]:
• There is no pan on the cooking zone.
• The pan is not compatible with induction.
• The bottom diameter of the pan is too small.
The control panel displays [ E ]:
• The electronic system is defective.
• Disconnect and replug the hob.
• Call after sales
One or all cooking zone cut-off:
• The safety system functioned.
• You forgot to cut-off the cooking zone for a long
time.
• One or more sensitive keys are covered.
• The pan is empty and its bottom overheated.
• The hob also has an automatic reduction of Booster
level and breaking Automatic overheating.
EN 43