Problem
The control board does not
work and no LED indicator comes
on
The operators do not work,
DL14 lit up,
DL6 and/or DL9 off
The operators do not work,
DL14 lit up,
DL6 and DL9 lit up,
DL10
and
DL11
off
operating the key devices
One of the operators does not
work,
DL14 lit up,
DL6 and DL9 lit up,
when pressing PULS1, PULS2, the
relay and the triac are activated
(DL4 or DL5 and DL17 or DL18 light
up)
The leaf does not reach the
stopper
The electrolock is not released
3

SPARE PARTS

If the control board needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
4

SCRAP

The control board, up until the end of its useful
life, must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner possible accidents and damage to
adjacent facilities will be avoided.
Cause
Main switch SW1 in "OFF"
Absence of control board power
supply
Electronic fuse F2 blown
Control board failed
D L 6 a n d / o r D L 9 o f f i n d i c a t e
obstacle or safety device error
F3 blown (whenever the safety
devices are fed by way of the AUX
2 4 V a c c o n t r o l b o a r d c a b l e
connectors)
The key device signal does not
reach the control board
when
Operator fuses F1 or F4 blown
Operator connections
Capacitor absent or defective
Operator defective
Run programming incorrect
The back pulse has not been
programmed
Electrolock or connections with
failure
MAINTENANCE AND DIAGNOSIS OF FAILURES
Solution
Place SW1 in "ON"
Reestablish the power supply
Replace F2 using another fuse of the
same value and investigate the cause
of failure of F2
Call the technical service
Remove the obstacle or check the
interior/safety on closings
Replace F3 using another fuse of the
same value and investigate the cause
of failure of F3. Check that the
connected devices do not represent an
overload
Check the devices and the connections
Replace F1/F4 using another cutout of
the same value and investigate the
cause of failure of F1/F4
Check connections
Install or replace capacitor
Replace operator
Carry out the programming correctly
Place DIP5 in ON
Check the connections and electrolock
Use only original spare parts.
}
The control board must be deposited in the
appropriate containers for subsequent recycling,
separating and classifying the different materials in
line with their nature. NEVER deposit it in domestic
rubbish or in landfills which are not suitably
controlled, as this will cause environmental
contamination.
Control board VIVO-M201(M)
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m201m

Table des Matières