MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Disconnect the device from the power supply before carrying out any maintenance operation.
1 Frequently check the installation in order to detect
any imbalance or sign of deterioration or wear. Do
not use the device if any repair or adjustment is
necessary.
2

SPARE PARTS

If the device needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
3

FAILURE DIAGNOSIS

SW1
Diagnosis items
L1
Opening device (A.T.) indicator activated
L2
Closing safety device contacts (SG.C) indicator
closed
L3
Shutter gate open indicator
L4
Radio code programming / receiving radio
code indicator (RSD)
L5
Power supply indicator
28
Installation Manual
T.E.
L4
L3
L1 L2
2 Check that the operation and safety devices
(photocells or safety strips), as well as their
installation, have not suffered any damage from the
weather or external agents.
Use only original spare parts.
L5
T.M.
RL1 RL2
F2
F1
Main fuse (5x20):
CLEVER01: 2.5A (230V/50Hz);
CLEVER01M: 6.3A (125V/ 60Hz)
F2
Peripheral power supply fuse (5x20): 350mA
T.E
Standby time regulation
T.M.
Operation time adjustment
S1
Main switch
SW1
Radio code programming mini-push button
RL1
Close relay
RL2
Open relay
F1
S1
P166N