Problem
The control panel does not
work and no LED indicator comes
on
The operator does not work
w h e n t h e k e y d e v i c e s a r e
activated
L5 lit up, L2 lit up,
L1 off when running the A.T. key
device
The leaf does not reach the
stopper
L2 lit up
The shutter gate opens but
does not close
L2 off
The shutter gate opens but
does not close
L2 lit up
The control panel works correctly
b u t
d o e s
n o t
o b e y
transmitter
4

SCRAP

The control panel, up until the end of its useful
life, must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner possible accidents and damage to
adjacent facilities will be avoided.
Cause
Main circuit breaker S1 in "OFF"
Power supply voltage absent
Main fuse F1 blown
Transformer or board failed
The key commands signal does not
reach the control board
Hard points in the shutter gate run
Operation time incorrectly set
Limit switches incorrectly adjusted
Closing safety device (photocell or
strip) enabled or defective
Peripheral power supply fuse F2
blown
Closing limit switch continuously
enabled or deteriorated
T r a n s m i t t e r c o d e i n c o r r e c t l y
programmed
t h e
Transmitter batteries flat
MAINTENANCE AND DIAGNOSIS OF FAILURES
Solution
Place S1 in "ON"
Restore the power supply voltage
Replace F1 using another fuse of the
same value and investigate the cause
of failure of F1
Call the technical service
Check the key command devices and
the connections
Move by hand and remove the hard
points
Adjust the T.M. power meter
Adjust the operator limit switches
(FCC, FCA)
Check the safety devices and the
connections
Replace F2 using another fuse of the
same value and investigate the cause
of failure of F2
Check FCC (of the operator) and its
connections
See "Radio code programming" on
page 26
Replace the batteries, checking the
instructions for the transmitter
}
The control panel must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying the different materials in line with their nature.
NEVER deposit it in domestic rubbish or in landfills which
are
not
suitably
controlled,
environmental contamination.
as
this
will
cause
29
CLEVER01 Control panel

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Clever01m

Table des Matières