MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Before
carrying
operation, disconnect the device from the
power supply.
Frequently check the facility in order to
discover any imbalance or sign of deterioration
or wear. Do not use the device if any repair or
adjustment is necessary.
A record of all repairs and maintenance operations
must be kept. The owner of the facility must keep
these records safe.
2

OPERATIONS COUNTER

1 Press ENTER to access the main programming menu.
The display lights up and D1 flashes.
D1
D2
Parameter
Operations carried out
ç
1
3

FAILURE DIAGNOSIS

Problem
The door does not make
any movement when a
key command is given
The door does not open
The door does not close
(the display shows C5 or
Ftço)
The
door
cannot
completely
close
(or
open)
out
any
maintenance
D3
D4
X
X
Cause
Absence of system power supply voltage
F1 blown
D102 (230V, 50Hz): 2.5A;
D102M (125V, 60Hz): 4A
Release switch open (the display shows STOP)
Command devices defective
Door overloaded
Door imbalanced
The safety device (photocell or strip) or its
cabling are open or defective
The safety device detects an obstacle
Run not programmed correctly

Every six months

1 Check that the operation and safety devices, as well
as their installation, have not suffered any damage
from the weather or external agents.
2 Check the operation of the flashing light.
3 Check manual operation.
2 Press the buttons ^ and
ç.
D3 and D4 show the number of operations
completed (see the table).
3 Press ESC to return.
Pre-
determined
Options or values
option
Indicates the cycles completed, multiplying
the indicated figure by an amount, for
example:
indicates 6,800 cycles completed
68
indicates 68,000 cycles completed
6.8
Solution
Reestablish the power supply
Replace using another fuse of the
same value and investigate the cause
of the failure
Check the switch, its adjustment and
cabling
Check the respective manuals
Remove the excess load
Balance the door
C h e c k t h e c a b l i n g a n d d e v i c e
(photocell or safety strip)
Remove the obstacle and try again
Programme again
until D1 shows the letter
V
VIVO-D102 Control board
English
53