3
PROGRAMMING SEQUENCE
General navigation through the programming parameters and menus
Display
ENTER
?
á
or
ESC
à
CL
Before entering the programming menus, it is
necessary to close the door or disconnect the device
and then reconnect.
Press the ENTER button to access the programming
menus.
The display shows "C"1 01 or "C"1 0 2.
Use the keys ^ and
to select the required values,
V
and confirm by pressing ENTER.
Use ESC to go back to the previous display.
To leave the programming menu, press ESC several
times until the display goes off or shows CL.
Prior Conditions Programming (D1= "C")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
C flashing. Press ENTER to confirm.
D2 flashes.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
D1
D2
Parameter
Motor turning direction
C
1
4
Closing safety device (photocell
5
or strip)
D1
ENTER
á
C
ESC
à
Select the value
using ^ and
V
until D1 shows the letter
V
until the required D2
V
D3
D4
0
1
0
2
0
0
1
0
1
1
STARTING UP AND PROGRAMMING
D2
ENTER
á
1
ENTER
(confirming)
à
Select the value
using ^ and
ESC
V
(unconfirmed)
à
1 Programme the prior conditions (see "Prior
Conditions Programming (D1= "C")" on page 49).
2 Programme the radio codes, along with the door
open/close (see "Radio code programming (only
with RSD) and door open/close programming (D1=
"P")" on page 50).
3 Programme
the
functioning
automatic standby time (see "Main Functions
Programming (D1= "F")" on page 50).
4 Programme the advanced functions (see "Advanced
Functions Programming (D1= "A")" on page 51).
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
If "motor turning direction" is selected after
pressing ENTER, the display shows
the door can be operated using the ^ and
to check turning direction. Press ESC to finish the
check.
5 Press ESC to return to the previous display.
Predetermined
Options
option
x
Disabled
x
Device not installed
Device without testing
Device with testing
D3 - D4
0 x
Select the value using
^ and
V
mode
and
the
until the required D3 and
V
. At this point
buttons
V
VIVO-D102 Control board
49