PROGRAMMING AND STARTUP

1

CONTROLS AND COMMANDS

J8
ANT.
L16
L17
J1
L6
STOP
ST1
L1 L2
ST1
ST2
SW2 functions
Functions during programming (DIP3=ON)
• DIP1=OFF and DIP2=OFF: programming the
opening and closing run (see page 49).
Functions during use (DIP3=OFF)
• DIP1=ON and DIP2=ON: optional automatic
closing mode (closing begins when standby time
finishes, but can be brought forward using a key
command) and community opening (the door
CANNOT be stopped using a key device whilst
opening).
During closing, ST1 (or the transmitter) carries out
shutdown and reverse movement.
The photocell shadow function is activated.
– with DIP4 = OFF: ST1 is active: with the door
open, pressing ST1 (or the transmitter) cancels
standby and closes the door.
– with DIP4 = ON: ST1 and ST2 are active: pressing
ST1, the transmitter or ST2 with the door open
cancels standby time and closes the door.
48
Installation Manual
J3
J2
J7
J6
J5
J4
L11
L7
L12
K4
CLOSE
Lamp.
L10
L8
L13
L9
ON
OFF
4
ST2
OFF
L3
L4
L5
N
L
BATTERY
POWER
GARAGE
FT
FCA FCC
230Vac
LIGHT
12V
4
F184AA
SW1 Main switch
SW2 Programming DIPs
ST1
Opening and closing mini-pushbutton (opening
only in some operating modes, see "Operation
modes" on page 41)
ST2
Closing mini-pushbutton (only in some
operating modes, see "Operation modes" on
page 41)
T.E.
Open door stand-by time adjustment (only works
in automatic mode, DIP1=ON)
PM.A Torque adjustment (maximum thrust) in opening
PM.C Torque adjustment (maximum thrust) in closing
J1
Operator model selector (IZAR 1 - IZAR 4)
J1
must
corresponding to the operator installed
(IZAR1 or IZAR4). Failure to do so may lead
to accidents.
P181C
• DIP1=ON and DIP2=OFF: automatic closing
mode (closing begins when standby time finishes)
and community opening (the door CANNOT be
stopped using a key device whilst opening).
During closing, ST1 (or the transmitter) carries out
shutdown and reverse movement.
The photocell shadow function is activated.
– with DIP4 = OFF: ST1 is active: with the door
open, pressing ST1 (or the transmitter) resets
standby.
– with DIP4 = ON: ST1 and ST2 are active: with the
door open, pressing ST1 (or the transmitter)
resets standby, whilst pressing ST2 cancels
standby and closes the door.
• DIP1=OFF and DIP2=ON: step-by-step closing
mode (the door remains open until the key device is
operated) and alternative stop (whilst opening, the
door can be stopped by pressing the key device).
The photocell shadow function is enabled but only
works if the opening operation is completed. For
this reason, if a close command is sent during
opening or alternative stop, opening is carried out
(DIP4=OFF) or it is ignored (DIP4=ON).
During closing, ST1 (or the transmitter) carries out
shutdown and reverse movement.
– with DIP4 = OFF: ST1 is active: during alternative
stop, pressing ST1 closes the door (if the
photocell shadow function is enabled, pressing
ST1 opens the door).
be