Operation Modes - Erreka VIVO-D103 Manuel De L'installateur

Armoire de commande pour l'actionneur « izar »
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3

OPERATION MODES

Automatic mode (DIP1=ON)
In automatic mode, the photocell shadow function is activated.
Step-by-step mode (DIP1 = OFF and DIP2 = ON)
In semi-automatic mode, the photocell shadow function is enabled but only works if the opening operation is
completed. For this reason, if a close command is sent during opening or alternative stop, opening is carried out
(DIP4=OFF) or it is ignored (DIP4=ON).
Opening (with alternative stop): this begins by
activating the key device (transmitter, magnetic key,
key switch, etc).
• With DIP4 = OFF, ST1 is active: the door can be
stopped by pressing ST1 or the transmitter
(alternative stop). During alternative stop, pressing
ST1 or the transmitter produces closing (if the
photocell shadow function is enabled, pressing ST1
opens the door).
ON
OFF
4
ON
OFF
4
G181E2
ON
OFF
4
ON
OFF
4
G181F2
ON
OFF
4
ON
OFF
4
G181G2
DESCRIPTION OF THE PRODUCT
Opening: this begins by activating the ST1 key device
(magnetic key, key switch, etc) or the transmitter.
• Community opening: during opening, the door
cannot be stopped by sending a key command.
S t a n db y : t h e d o o r r e m a i n s o p e n d u r i n g t h e
programmed time.
• With DIP4 = OFF, ST1 is active:
– With DIP2 = OFF, pressing ST1 resets standby.
– With DIP2 = ON, pressing ST1 cancels standby
time and closes the door.
• With DIP4 = ON, ST1 and ST2 are active:
– With DIP2 = OFF, pressing ST1 resets standby,
whilst pressing ST2 cancels standby and closes
the door.
– With DIP2 = ON, pressing ST1 or ST2 cancels
standby time and closes the door.
Closing: the closing operation starts once stand-by
time is finished.
• During closing, ST1 (or the transmitter) carries out
shutdown and reverse movement.
• With DIP4 = ON, ST1 and ST2 are active; the door
can be stopped (alternative stop) during opening by
pressing ST1 or the transmitter. During alternative
stop, pressing ST1 or the transmitter produces
opening, whilst pressing ST2 will cause closing (if
the photocell shadow function is enabled, ST2 does
not have any effect).
If ST2 is pressed during opening, the door stops and
then closes.
Standby: the door remains open indefinitely until the
key device is operated.
• With DIP4 = OFF, ST1 is active: with the door open,
pressing ST1 or the transmitter closes the door.
• With DIP4 = ON, ST1 and ST2 are active: with the
door open, pressing ST2 closes the door.
Closing: the closing operation starts when the key
device is operated.
• If ST1 or the transmitter is activated during closing,
the door stops, reverses operation direction and
opens completely.
VIVO-D103 / ADB30 Control board
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Adb30

Table des Matières