Total Open/Close Programming - Erreka VIVO-M201 Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAMMING AND STARTUP
4

TOTAL OPEN/CLOSE PROGRAMMING

Programming the total run of the gate is done using the ST1 mini-push button, the total operation device (A.T.)
or the transmitter.
Before making the programming, ensure there is no person, animal or object in the radius of action of
the gate and the mechanism.
Start programming mode
Programme opening
34
Installation Manual
1 Close the gate by pressing PUL1.
2 Place DIP1 and DIP2 in "ON" (operation
programming); DIP3, DIP4, DIP6, DIP7, DIP9 and
DIP10 in "OFF".
DL3 comes on and remains static.
3 Installations with electrolock: place DIP5 in "ON"
(back pulse).
4 In operators with mechanical absorbers (such as
hydraulic motors), place DIP8 in "OFF" (electric soft
stop disabled).
1 Start the opening of leaf 1: press ST1; leaf 1
begins to open.
2 Start slow down on opening of leaf 1 (with
DIP8=ON only): press ST1 at the point chosen for
the start of deceleration (DA1) (except in hydraulic
operators).
3 Finish opening of leaf 1: press ST1 in leaf 1 open
position.
4 Start the opening of leaf 2: press ST1; leaf 2
begins to open.
5 Start slow down on opening of leaf 2 (with
DIP8=ON only): press ST1 at the point chosen for
the start of deceleration (DA2) (except in hydraulic
operators).
6 Finish opening of leaf 2: press ST1 in leaf 2 open
position.
When using the control board with a single operator
(operator A1, see Fig. 3 on page 29), the times
corresponding to operator A2 must be zero. To do
this, instead of carrying out steps 4, 5 and 6, press
ST1
three
times
consecutively
DIP8=OFF).
(twice
with

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m201m

Table des Matières