Settings Menu - Bosch D-tect 150 Professional Notice Originale

Masquer les pouces Voir aussi pour D-tect 150 Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
OBJ_BUCH-844-006.book Page 25 Monday, August 30, 2010 10:44 AM
"Settings" Menu
To access the "Settings" menu, press the setup
button 14.
To exit the menu, press the start button 11. The
current settings are saved. The standard start
display for the measuring process is activated.
Navigating in the Menu
Press the setup button 14 to scroll down.
Press the selection buttons 10 and 12 to select
the values:
– Selection button 10 will select the right-hand
or next value.
– Selection button 12 will select the left-hand
or previous value.
Language
In the "Language" menu, you can change the
language of the menu navigation. The default
setting is "English".
Cut-off Time
In the "Cut-off time" menu, you can set certain
time intervals after which the measuring tool
shall automatically shut off when no measure-
ments are taken or settings are carried out. The
default setting is "5 min".
Light Duration
In the "Light duration" menu, you can set a time
interval within which the display 16 shall be illu-
minated. The default setting is "30 s".
Brightness
In the "Brightness" menu, you can adjust the
brightness of the display backlight. The default
setting is "Max".
Bosch Power Tools
Tone Signals
In the "Tone signal" menu, you can limit when
the measuring tool shall emit an audio signal. The
precondition for this is that the signal has not
been switched off via the audio signal button 13.
– The default setting is "Wallobjects": An audio
signal sounds after each button press, and
whenever a wall object is under the sensor
range. Additionally, a short-beat warning sig-
nal is given for "live" wires.
– With the setting "Live wire", an audio signal
sounds after each button press, as does the
warning signal for "live" wires (short-beat
signal), when the measuring tool indicates a
power line.
– With the setting "Keyclick", a tone signal
only sounds after a button press.
Default Mode
In the "Defaultmode" menu, you can set the de-
fault operating mode that is to be pre-set after
switching on the measuring tool. The default
setting is "Universal mode".
"Extended Settings" Menu
To access the "Extended settings" menu, press
the setup button 14 and the On/Off button 15 at
the same time when the measuring tool is
switched off.
To exit the menu, press the start button 11. The
standard start display for the measuring proc-
ess is activated and the settings are saved.
Navigating in the Menu
Press the setup button 14 to scroll down.
Press the selection buttons 10 and 12 to select
the values:
– Selection button 10 will select the right-hand
or next value.
– Selection button 12 will select the left-hand
or previous value.
Device Information
In the "Device Infos" menu, you can access in-
formation on the measuring tool, e.g. the "Oper-
ation Time".
In the "Restore Settings" menu, you can restore
the factory settings.
1 609 929 X40 | (30.8.10)
English | 25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Professional d-tect 1503 601 k10 005

Table des Matières