All products to be stored, that are not wrapped or packed, must be covered in order
to avoid unnecessary corrosion of the inner parts of the cabinet, including the
evaporator.

Electrical connection

The cabinet is intended for connection to alternating current. The connection values
for voltage (V) and frequency (Hz) are given on the nameplate inside the cabinet.
Power must be connected via a wall socket. The wall socket should be easily
accessible.
All earthing requirements stipulated by the local electricity authorities must be
observed. The cabinet plug and wall socket should then give correct earthing. If in
doubt, contact your local supplier or authorized electrician.
Warning !
This cabinet must be earthed.
The flexible cord fitted to this appliance has three cores for use with a 3-pin 13-Amp
or 3-pin 15-Amp plug. If a B.S. 1363 (13-Amp) fused plug is used, it should be fitted
with a 13-Amp fuse.
Important
The wires in this mains lead are coloured in accordance with the following code:
GREEN-AND-YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
The colours of the wires in the mains lead of this appliance might not correspond
with the colour marking identifying the terminals in your plug.
Proceed as follows:
Connect the GREEN-AND-YELLOW wire to the plug terminal marked by "E" or an
earth symbol, or coloured GREEN-AND-YELLOW.
Connect the BLUE wire to the plug terminal marked "N" or coloured BLACK. Connect
the BROWN wire to the plug terminal marked "L" or coloured RED.

Starting up

+ -
P
Plug in the cabinet
To start, press the ON/OFF key into position "I"
The figures that now appear in the display give the actual temperature in the cabinet
and indicate that power is connected.