Overload Cut-Out 2 X 230 V Socket-Outlets; Switching Off The Engine; Connecting Consumers To The Generator; Cleaning, Maintenance, Storage And Ordering Of Spare Parts - EINHELL TC-PG 5500 WD Instructions D'origine

Masquer les pouces Voir aussi pour TC-PG 5500 WD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Start the engine by turning the ignition key in
the ignition lock (Fig. 1/Item 10). Once the en-
gine has started, turn the ignition key immedi-
ately back to its initial position. If you actuate
the ignition key again while the engine is run-
ning, you will damage the starting system.
Push the choke lever (11) back after the engi-
ne has started.
6.1.2 Starting up with the reversing starter
Open the petrol cock (13) by turning it down
Move the ON/OFF switch (10) to position
„ON" with the key.
Move the choke lever (11) to position IØI.
Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
Push the choke lever (11) back again after
the engine has started.
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting in
hand injuries. Wear protective gloves when star-
ting the equipment.

6.2 Connecting consumers to the generator

Connect the equipment you want to use to
the 230 V~sockets (3)
Important: These sockets may be loaded con-
tinuously (S1) with 3000W and temporarily
(S2) for a maximum of 5 minutes with 3300W.
Set the selector switch (Fig. 3/Item 27) to
the right to activate the 400V 3~ socket.
Important: This socket may be loaded conti-
nuously (S1) with 3600 W and temporarily for
a maximum of 2 minutes with 5500 W (from a
standstill, with the generator cooled down) or
for a maximum of 5 minutes with 4800 W (at
operating temperature).
The generator is suitable for 230 V~ AC ap-
pliances.
Do not connect the generator to the domestic
power network as this may result in damage
to the generator itself or to other electrical
appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in diffi cult conditions.
Anl_TC-PG_5500_WD_SPK9.indb 22
Anl_TC-PG_5500_WD_SPK9.indb 22
GB

6.3 Overload cut-out 2 x 230 V socket-outlets

Important! The generator is fi tted with an
overload cut-out.
This shuts down the sockets (3). You can restart
the sockets (3) by pressing the overload cut-out
(5).
Important! If this happens, reduce the elec-
tric power you are taking from the generator
or remove any defective connected applian-
ces.
Important! Defective overload cut-outs must
be replaced only by overload cut-outs of
identical design and with the same perfor-
mance data. If repairs are necessary, please
contact your customer service center.
6.4 Switching off the engine
Before you switch off the generator, allow it
to run briefly with no consumers so that it can
„cool down"
Move the key (Fig. 1/Item 10) to the „OFF"
position
Close the petrol cock
7. Cleaning, maintenance, storage
and ordering of spare parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning
and maintenance work on the equipment.
Notice! Switch off the machine immediately and
contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or
misfires
7.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could
attack the plastic parts of the equipment. En-
sure that no water can seep into the device.
- 22 -
17.08.2017 07:55:53
17.08.2017 07:55:53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.525.60

Table des Matières