Les langues disponibles

6. Rotate manual lock unloader lever to the closed position to allow
air tank pressure to build. noTe: Pump will not operate with the
manual lock unloader lever in the open position.
7. Allow compressor to pump up to blow off pressure.
noTe: If any unusual noise or vibration is noticed, stop the compressor
and refer to the troubleshooting section.
noTe: The air compressor pump is capable of running continuously.
To prolong the air compressor's life, it is recommended to run at high
throttle 50-75% of the run time and idle for 5% of the run time
8. Attach hose and accessory.
CAUTION: Risk of unsafe operation. Compressed air from the unit
may contain water condensation and oil mist. Do not spray unfiltered
air at an item that could be damaged by moisture. Some air operated
tools or devices may require filtered air. Read the instructions for the
air tool or device.
9. Adjust regulator (F) to desired setting. See regulator under
Features.
Shut-down
1. Stop engine, see engine's instruction manual for correct
procedure.
noTe: If finished using compressor, follow Steps –6.
. Turn regulator knob (F) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank. See Draining Air Tank under Maintenance.
WARNING: Risk of bursting. Drain air tank daily. Water will condense
in air tank. If not drained, water will corrode and weaken the air tank
causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non freezing area.
MAInTEnAnCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure engine ON/OFF switch (C) is in the OFF position.
. Disconnect spark plug wire.
3. Drain air tank.
4. Allow air compressor to cool down before starting service
noTe: All compressed air systems contain maintenance parts (e.g.
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
noTe: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
noTe: Any service operations not included in this section should
be performed by a D
WALT factory service center or a D
e
authorized service center.

Maintenance Chart

Procedure
Check safety valve
Inspect air filter +
Drain air tank
Check pump oil level
Change pump oil** +
Oil leak inspection
Inspect drive belt
Check drive belt tension
15
Daily
Weekly Monthly
1 year or
200 hours
X
X
X
X
X
X
X
WALT
e
X

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D55270tD55271D55271tD55275D55276D55270t série ... Afficher tout

Table des Matières