When either time control, temperature control, or a combination of both is selected,
each program is followed by a defrost and then changeover to the storage program.
The storage program can be used alone.
1. Storage program.
If this program is selected, the cabinet operates as a normal refrigerator and is
controlled by the set temperature.
2. Time-controlled chilling.
The compressor runs continuously until the set time has elapsed. The control then
changes over to the storage program.
3. Temperature-controlled chilling.
The compressor runs continuously until the set temperature is reached. The control
then changes over to the storage program.
4. Combination of time and temperature-controlled chilling.
Combined time and temperature control operates as follows:
1.
If the set temperature is reached before the set time has elapsed, this
temperature is maintained until the time has elapsed. The control then
changes over to the storage program.
2.
If the set temperature is not reached before the set time elapses, chilling
continues until the set temperature is reached. The control then changes
over to the storage program.
Program and
program sequence setting
The program keys
righthand corner.
In
the LED will either flash or light up continuously. (Each time the program key
is pressed the function will change).
1.
Flashing LED indicates that the program has not been started. The cabinet
is ready for programming.
2.
LED continuously on indicates that the program has been started.
76-504-0981
contain a red LED (light emitting diode) in the top