Temperature-Controlled Chilling; Combination Of Time And Temperature-Controlled Chilling - Gram KP 660 Mode D'emploi

Masquer les pouces Voir aussi pour KP 660:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55
(If a change of time setting is required, see section "Changing temperature and time
settings").
The program is stopped and the LED goes out when the program time has elapsed.
The program can now be completed by pressing
. The LED will go out. A defrost
follows and the control switches over to the storage program.

Temperature-controlled chilling.

Program setting.
Press
; the LED will then flash and the set temperature will be displayed.
(If a change of temperature setting is required, see section "Changing temperature
and time settings").
Program sequence.
The program can be started by pressing
. The LED lights up continuously. The
display alternates every 5th second, between cabinet temperature and set
temperature.
(If a change of temperature setting is required, see section "Changing temperature
and time settings").
The program is stopped and the LED goes out when the set temperature is reached.
The program can also be stopped by pressing
. The LED will go out. A defrost
follows and the control switches over to the storage program.

Combination of time and temperature-controlled chilling.

Program setting.
The storage program, time-controlled chilling program and temperature-controlled
chilling program must be set as described under the headings above.
Program sequence.
The program is started by pressing
and
. The LEDs will light up continuously.
The order in which the programs are started is of no importance. The display
alternates every 5th second, between cabinet temperature and programmed time.
The set temperature can be displayed by holding down one of the arrow keys and at
the same time pressing
. But remember, the arrow key must be pressed first.
The set time can be displayed by holding down one of the arrow keys and at the
same time pressing
. But remember, the arrow key must be pressed first.
(If a change of temperature or time setting is required, see section "Changing
temperature and time settings").
76-504-0981