Preferred Pellet Vent Termination Clearances

The stove vent must terminate on the outside of the building. Horizontal terminations must extend a minimum
of 12" from the wall. Vertical terminations must protrude a minimum 24" from the roof surface. In addition, all
clearances listed below must be met. SEE FIGURE 7.
Must have an approved cap (to prevent water from entering) or a 45° downturn with rodent screen.
If the termination is located on a windy side of the house, we suggest using an approved house shield to prevent
soot from building up on the side of the house.
A vent must not be located where it will become plugged by snow or other material.
C
Figure 7: Vent Termination
A: A Minimum 4' clearance below or beside any door or
window that opens. (This clearance may be reduced
to 18" if using outside air). We recommend the door or
window be kept closed during operation. Minimum 1'
clearance below or beside any window that does not
open.
B: Minimum 1' clearance above any door or window that
opens.
C: Minimum 2' clearance from any adjacent building.
D: Minimum 7' clearance above any grade when adjacent to
public walkways.
NOTE: Vent may not terminate in covered walkway or
breezeway.
E: Minimum 2' clearance above any grass, plants, or other
Check for parts online at www.castlestoves.com or call 800-450-EDGE (3343) M-F 8-5
H
X
B
H
A
F: Minimum 3' clearance from any forced air intake of any
G: Minimum 2' clearance below eaves or overhangs.
H: Minimum 1' clearance horizontally from combustible wall.
X: Must be a minimum of 2' above the roof.
Operator's Manual
Serenity Pellet Stove
A
F
E
combustible materials.
other appliance.
G
F
D
13