Outside Air Connection; Mobile Home - CASTLE Serenity Instructions D'utilisation

Masquer les pouces Voir aussi pour Serenity:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Outside Air Connection

Connection from the intake pipe (2" diameter pipe in rear of stove,
See Figure 8) to the outside of the house is REQUIRED for mobile
home installation. It is recommended in tightly sealed homes
with exhaust fans such as kitchen or bathroom fans. This will
eliminate poor performance due to negative pressure.
Only noncombustible pipe 2" (or greater) in diameter is approved
to use for outside air connections (straight or flexible).
NOTE: PVC pipe is NOT approved and should NEVER be
connected to the stove.
HINT: A Castle Pellet Stove air inlet will accept
automotive exhaust pipes and couplers
If the air inlet is connected to the outside, it MUST be terminated
with a vertical 90
bend (down) or with a wind hood. Failure to do
º
so could result in a burn back during high winds blowing directly
up the air inlet during a simultaneous power failure.
Blockage, excessive length, or extra bends in the air intake pipe
will starve the stove of combustion air. A 90º bend is equivalent in
restriction to approximately 30" of straight inlet pipe.

Mobile Home

Installation in a mobile home should be in accordance with the
manufactured home and safety standard. Department of Housing
and Urban Development (HUD) CITE: 24CFR3280.707 stating
this stove must be vented to the outside. In addition to the
standard installation instructions, the following requirements are
mandatory for installation in a mobile home:
1. The stove must be permanently attached to the floor.
2. Stove must have an outside air source.
3. Stove must be electrically grounded to the steel chassis
of the mobile home.
4. All vertical chimney vents must have wall supports.
5. All exhaust systems must have a spark arrestor.
6. Check with local building officials to see if other codes
may apply.
Check for parts online at www.castlestoves.com or call 800-450-EDGE (3343) M-F 8-5
Operator's Manual
Serenity Pellet Stove
WARNING
CARBON MONOXIDE POISONING HAZARD. DO
NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM. DO NOT INSTALL IN A SLEEPING
ROOM.
CAUTION
THE OPERATION OF EXHAUST FANS SUCH AS
BATHROOM FANS, ATTIC FANS, ETC. MIGHT
STARVE THE PELLET STOVE OF COMBUSTIBLE AIR
CREATING A NEGATIVE PRESSURE IN THE ROOM.
PROVIDE ADEQUATE VENTILATION IN THE ROOM
ACCOMPANYING THE PELLET STOVE. IF NOT, THE
PRESSURE SWITCH MAY SHUT OFF OPERATION
OF THE PELLET STOVE.
THE
STRUCTURAL
MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
INTEGRITY
OF
THE
15